Stocker_logo_wob.gif (3142 bytes)

MRU Analysers

Home Up Feedback Contents

 

Bacharach Analysers
MRU Analysers

Providing a new generation of measuring devices for control of gas furnaces as well as for servicing oil and gas fired burners.

MRU guarantees reliable, perfected and field-proven technology.  Customers know that MRU means security, operability, and easy handling.

Delta 65

 
The starter unit for professional flue gas analysis. A handheld unit, easy to handle for all control and adjustment measurements.

Features:

  • Unit with protection cover, fixing magnet and large condensate trap
  • 180 mm gas sampling probe with 1,5 m hose
  • Rubber protection case with magnet
  • Highly legible LCD display (4 lines)
  • Infrared interface for MRU IR printer drive
  • RS 232 interface with 50 data memory
  • Rechargeable batteries
  • Battery charger for 100-240Vac line power

Technical Data
O2:   0-21 % Draft/Chimney-Draft:   -5  -  +35 hPa
CO:   0-10000 ppm Exhaust-Temperature:  0-650 °C
Ambient Temperature: + 5 - + 45 °C WxHxD:  74x145x35 mm
Battery-Capacity:   > 15 h Weight:   500 g
Inlet-Temperature:   0-100 °C
 

Calculated Values
CO: unv. ppm, mg/m3, mg/x%O2 Efficiency:     0-120 %
CO2:  in % Dew Point:   ° C
Lambda: 1,....    
Losses:   in %
Top of Page

 

Spectra 2000 Spectra.jpg (41739 bytes)

 
Professional handheld flue gas analyzer for all control and adjustment measurements at oil and gas burners as well as modern condensing boilers.

Features:

  • Very large, illuminated display shows 7 measured values simultaneously
  • Unit internally heated
  • Continuous chimney draft measurement
  • Microprocessor controlled battery charging and - conditioning
  • Graphical mainstream detection
  • Automatic CO cut-off by means of solenoid valve, with separate rinsing pump for sensor protection incl. individually programmable threshold values
  • Simultaneous use of up to 3 sensors
  • Integrated condensation trap, triple sampling line, black
  • Two year limited warranty
 

Technical Data
O2:   0-21 % Operating Temperature: + 5 - + 45 °C
CO:   0-4000 ppm Exhaust-Temperature:   650 °C
Draft/Pressure:   ± 100 hPa NO(x):   0-2000 ppm
Ambient Temperature:   + 5 - + 45 °C WxHxD:   150x200x55 mm
Battery-Capacity:   > 8 h Weight:   1200 g
Draft/Chimney-Draft: ± 40 hPa
 

Calculated Values
CO:   ppm undiluted Efficiency:     0-120 %
CO2:   in % Dew Point:   ° C
Lambda:   1,....
Losses:   in %
Top of Page

 

Delta 2000 CDD2000_1.gif (248250 bytes)

 
Compact measuring unit in a carrying case, completely equipped for control and adjustment measurements at gas and oil burners as well as modern condensing boilers. Equipped with large CO-sensor (option) suitable for measurements of solid matter.

Features:

  • Continuous analysis of O2, CO ppm, CO undiluted, CO2, Lambda, efficiency, losses, combustion air temperature, exhaust gas temperature (separate temperature measurement)
  • Continuous chimney draft measurement
  • RS 232-computer interface
  • Battery and mains operated
  • 300 mm gas sampling probe Ø 8 mm, 2,7 m hose and transport case
  • Very large, illuminated display shows 7 measured values simultaneously
  • Automatic CO cutoff by means of solenoid valve, with separate rinsing pump for sensor protection incl. individually programmable threshold values
  • Battery capacity for 1 day
  • Print out of measuring results
  • Simultaneous use of up to 3 sensors
  • Easy to use software and individual settings possible
  • Automatic measuring program
 

Technical Data
O2:   0-21 % Draft/Chimney-Draft:   ± 20 hPa
CO:   0-10000 ppm Exhaust-Temperature:   650 °C
CO:   0-10000 ppm CO2:   in %
NO:   0-2000 ppm WxHxD:   195x90x190 mm
Ambient Temperature:   + 5 - + 45 °C Weight:     1900 g
Inlet-Temperature: 100 °C
 

Calculated Values
CO:   ppm undiluted NO(x):   mg/m³
CO:   ppm x% O2 NO(x):   mg/ kWh
CO:   mg/m³ NO(x):   mg/ MJ
CO:   mg/ x% O2 NO2:   mg/ m³
CO:   mg/kWh NO2, referred: mg/ x% O2
CO:   mg/MJ Efficiency:   0-120%
CO2:   in % Losses:   in %
NO:   ppm/ 14% CO2 (Hbg. Modell) Lambda: 1,....
NO(x):   ppm
NO(x): ppm undiluted
Top of Page

 

Nova 2000D2000_1.gif (248250 bytes)

 
Compact measuring unit in a carrying case, ideally designed for the heating engineer but just as well suitable for the high demands of the chimney sweeper.

Features:

  • Analysis of oxygen and carbon monoxide with combustion calculations and measurement of flue gas temperature and combustion air temperature
  • Automatic internal test and control of soft- and hardware functions
  • All known fuel types, user selectable, integrated in the firmware of unit
  • Variable O2 referencing for emission reports
  • Acoustical CO threshold value, graphical flue gas core flow search
  • Optimized filter elements for protection against dust and soiling
  • Short ambient air temperature plug
  • With alarm LED for important anayzer status and start-up self-test
  • RS232 serial port
  • 8-line backlit graphical display
  • Line power supply device (90-240Vac / 12Vdc, 5,5A)
  • Internal battery power supply, 8 hours minimum operation
  • Smart battery charger integrated
  • Gas sampling probe with probe tube Æ 8 x 300 mm and 2,7 m sampling line
  • Data storage for 300 measurements, with search function
  • Optimized condensate trap and filter
  • High speed, thermal printer, width 58 mm, with easy paper loading
  • RS232 interface cable, user manual
  • Compact and robust transport case
  • CO protection “Purafil” filter against acid gases (NOx and SO2)
 

Technical Data
O2:   0-21 % Exhaust-Temperature:   650 °C
CO:   0-10000 ppm NO(x):   0-2000 ppm
Draft/Pressure:   ± 100 hPa WxHxD:   500x350x240 mm
Draft/Chimney-Draft:   ± 20 hPa Weight:  9500 g
Operating Temperature: + 5 - + 45 °C
 

Calculated Values
CO:   ppm x% O2 NO(x):   mg/m³
CO:   mg/m³ NO(x):   mg/ kWh
CO:   mg/ x% O2 NO(x):   mg/ MJ
CO:   mg/kWh NO2:   mg/ m³
CO:   mg/MJ NO2, referred: mg/ x% O2
CO2:   in % Efficiency:   0-120%
NO:   ppm/ 14% CO2 (Hbg. Modell) Losses:   in %
NO(x):   ppm Lambda: 1,....
NO(x):   ppm undiluted
Top of Page

 

Vario Plus Industrial Vp.gif (313230 bytes)

 
Compact unit in a aluminium framed case suitable for continuous measurements. For control- and adjust measurements at industrial burners and industrial plants. For control and adjustment measurements at oil and gas burners, for gas-fired burners and examination of modern condensing boilers.

Features:

  • Continuous analysis of O2, CO ppm and NO(x), separate measurement of combustion air and exhaust gas temperature
  • Calculated will be CO undiluted, CO2, Lambda, efficiency, losses, mg/m3, mg/kwh, dew point.
  • Referred oxygen ( 3 %, 8 %, 13 % ) for CO- and NO-calculation user definable
  • Continuous chimney draft measurement
  • Differential pressure measurement
  • Software and hardware prepared for integration of infrared measurement (CO2, HC) and SO2-/NO2-sensors (electrochemical) as well as for heated, controlled gas sampling, cooling with automated condensation disposal
  • RS 232-Computer-interface
  • Data memory for 300 measurements
  • Battery and mains operated
  • 300 mm gas sampling probe with 2700 mm hose
  • Integrated printer with document proof printing paper.
  • CO sensor cut-off by means of solenoid valve and 2. pump for immediate CO-sensor-flush (protection of CO-sensor) and fast readiness of CO-sensor
  • Individual programmable CO-threshold
  • Large, illuminated, well legible LCD display
  • AUX-socket for additional sensors
  • soot measurement
  • Logical, menu-guided operation, individually definable menu sequences
  • Peltier cooler
  • Heated gas sampling
  • Upgradeable with up to 6 sensors simultaneously
  • Socket for external keyboard
  • Ridged and practical aluminium framed case

 


Technical Data
O2:   0-21 % Exhaust-Temperature:   650 °C
CO:   0-4000 ppm NO2:   0-1000 ppm
CO:   0-20000 ppm SO2:   0-2000 ppm
NO:   0-2000 ppm CO2:   0-20 %
Draft/Pressure:   ± 100 hPa HC:   0-5000 ppm
Ambient Temperature:   + 45 °C WxHxD:   500x275x210 mm
Inlet-Temperature:   150 °C Weight: 11.500 g
Draft/Chimney-Draft:   ± 20 hPa
Operating Temperature: + 5 - + 45 °C
 

Calculated Values
CO:   ppm x% O2 NO(x):   mg/m³
CO:   mg/m³ NO(x):   mg/ kWh
CO:   mg/ x% O2 NO(x):   mg/ MJ
CO:   mg/kWh NO2:   mg/ m³
CO:   mg/MJ NO2, referred: mg/ x% O2
CO2:   0-20% Efficiency:   0-120%
NO:   ppm/ 14% CO2 (Hbg. Modell) Losses:   in %
NO(x):   ppm Lambda: 1,....
NO(x):   ppm undiluted
Top of Page

  

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone

 

 

 

Home ] Up ] Feedback ] Contents ]

Send mail to info@stocker.be for more information on our products and services.



Send mail to webmaster@stocker.be with questions or comments about this web site.
Copyright © 2003-2006 Stocker Industrie S.A./N.V.
Last modified: 05/01/07 01:31